Lookup repository initialization fails
If the lookup repository does not initialize, check the global.applicationControlDirectory parameter in the config/config.cfg file, and then start the jobs again with the correct parameter values.
Symptoms
The initial command file of Lookup Manager is in the input directory, but the initialization fails. The state files of the ITE applications are not present or do not change their status in the control directory.
Causes
The path to the control directory is not set correctly for Lookup Manager and ITE jobs. They must not differ from each other. Every job must use the same folder.
Resolving the problem
- Check the global.applicationControlDirectory parameter in the config/config.cfg file of each ITE application and Lookup Manager application.
- Check the Streams Console for the correct setting of the global.applicationControlDirectory submission parameter.
- Recompile the jobs with the updated configuration, or cancel and resubmit the jobs using the correct parameter values.